I recently realised that nanomole and nanomolar are not the same thing. For years I read “25 nmol” on a primer order sheet and quietly filed it in my head under “some kind of weight.” It is nothing of the sort. If you have done the same, welcome, you are in good company, and the fix takes about five minutes.
The reason it is worth those five minutes is sequencing. That is where mixing up an amount with a concentration stops being a harmless slip and starts costing you reads.
A short story about counting molecules
In 1811 the Italian scientist Amedeo Avogadro proposed that equal volumes of gas, at the same temperature and pressure, contain the same number of particles. He never knew how many. That number was pinned down later, and the French physicist Jean Perrin named it in Avogadro’s honour. The word “mole” itself came from the German chemist Wilhelm Ostwald, who needed a convenient name for a chemist’s unit of counting.
So what is a mole? Not a weight, and not a volume. It is a count. Since the 2019 redefinition of the SI units, one mole is exactly 6.02214076 × 1023 entities. A nanomole is a billionth of that, roughly 602 trillion molecules. Big enough to sound impressive, small enough to fit in the bottom of a microcentrifuge tube.
Amount versus concentration
Here is the whole idea in one line.
- Nanomole (nmol) is an amount: how much stuff is in the tube.
- Nanomolar (nM) is a concentration: how much stuff is packed into each litre.
Think of sugar and tea. The sugar in grams tells you how much you have. How sweet the tea tastes depends on the volume of water you dissolve it in. Same sugar, very different cup.
The two are linked by volume:
amount = concentration × volume
which flips into
concentration = amount ÷ volume
A handy shortcut worth memorising: 1 nM is the same as 1 fmol per µL. Work it through and the units collapse neatly (10−9 mol per 106 µL is 10−15 mol per µL). This one trick makes sequencing calculations much less painful.
Where primers fit
Your instinct about primers is half right. They do arrive as an amount, the synthesis scale on the order sheet, for example 10 nmol. You then choose a volume of water to make a stock. Add 100 µL to 10 nmol and you get 0.1 nmol per µL, which is a 100 µM stock. Add 1 mL instead and the same 10 nmol gives a 10 µM stock.
The amount never changed. Only the concentration did. Your PCR then asks for a final concentration, typically around 0.2 to 0.5 µM, which is a different number again.
Why mass is not the same as molecules
Now to libraries, the place where this really bites.
A fluorometer such as Qubit reports mass concentration, in ng/µL. A sequencer, however, does not care how many nanograms you have. It cares how many molecules it can load. And the number of molecules in one nanogram depends on how long the fragments are.
Take 1 ng of DNA. If the fragments are 200 bp, that is about 7.6 fmol. If they are 1,000 bp, it is about 1.5 fmol. Same mass, five times fewer molecules, simply because each fragment is five times heavier.
That is why you need two measurements, not one: the concentration from Qubit, and the average fragment size from a Bioanalyzer, TapeStation or Fragment Analyzer. Then you convert:
nM = (ng/µL × 106) ÷ (660 × average fragment size in bp)
Where does 660 come from? It is the approximate average mass, in g/mol, of one base pair of double-stranded DNA. Some suppliers use 650 instead. The difference is about 1.5 percent, which is not worth losing sleep over, but do stick with one value so your numbers stay comparable.
A worked example
Suppose Qubit gives your library as 2 ng/µL, and the TapeStation says the average size is 500 bp.
- Multiply the concentration: 2 × 106 = 2,000,000.
- Work out the denominator: 660 × 500 = 330,000.
- Divide: 2,000,000 ÷ 330,000 ≈ 6.06 nM.
Now say your protocol wants the library at 4 nM. Take 10 µL of your library and use C1V1 = C2V2. The final volume is 10 × 6.06 ÷ 4 ≈ 15.2 µL, so you add about 5.2 µL of water.
Here is the part I find rather satisfying. Before dilution you had 10 µL at 6.06 nM, which is about 61 fmol. After dilution you have about 15.2 µL at 4 nM, which is still about 61 fmol. Diluting lowers the nM, but the nmol (or fmol) never moves. Amount and concentration, side by side, doing exactly what they should.
Platform by platform
Pooling barcoded libraries. Pool by equal molarity, not equal nanograms. Pool by mass and the short libraries get more molecules, so more reads, while your longer libraries quietly go hungry.
Illumina. Libraries are normalised in nM, then denatured and diluted to a final loading concentration in pM. Too high and you over-cluster. Too low and your yield suffers. Follow your kit for the exact target, because it differs between instruments and chemistries.
PacBio. Loading is also set as a concentration in pM, so the same molarity logic applies.
Oxford Nanopore. This is the interesting exception. Loading is generally given as an amount, in fmol, not a concentration. Imagine a protocol asks for 50 fmol of your 6.06 nM library. Since 6.06 nM is 6.06 fmol/µL, you need 50 ÷ 6.06 ≈ 8.3 µL. The shortcut from earlier earns its keep here. Always check the target amount in your own kit.
Adapters and primers. Adapter ligation depends on the molar ratio of adapter to insert, not on grams. Amplicon panels and PCR depend on final primer concentration.
A few pitfalls
- Use the average library size, not the size of one lovely sharp peak, because a smear has a distribution.
- The 660 formula assumes double-stranded DNA. If your library is single-stranded, or you quantify by qPCR, your kit may use a different conversion, so follow its instructions.
- Watch your prefixes. µM and nM are a factor of 1,000 apart, which is exactly the sort of gap that ruins a run.
Quick cheat sheet
| Unit | Measures | Think of it as | Typical use |
|---|---|---|---|
| nmol, fmol | Amount | Sugar in the bag | Primer synthesis scale, Nanopore loading |
| nM, pM, µM | Concentration | Sweetness of the tea | Pooling, dilutions, Illumina and PacBio loading |
| ng, µg | Mass | Weight on the balance | Qubit readings, input DNA |
If there is a “per litre” hiding in the unit, it is a concentration. If not, it is an amount.
So the next time your sequencing yield looks strange, check your units before you blame the flow cell. Mine have been guilty more than once.
Related Content
- Sanger, Illumina and Oxford Nanopore sequencing compared
- How to load an Oxford Nanopore flow cell
- PacBio HiFi versus Nanopore accuracy
References
Illumina. (n.d.). Converting ng/µl to nM when calculating dsDNA library concentration (Knowledge Article 000001240). https://knowledge.illumina.com/library-preparation/dna-library-prep/library-preparation-dna-library-prep-reference_material-list/000001240
New England Biolabs. (n.d.). Nucleic acid data. https://www.neb.com/tools-and-resources/usage-guidelines/nucleic-acid-data


No comments:
Post a Comment