When your RNA is locked inside a Tempus tube, you need a protocol that was built for it. The Tempus Spin RNA Isolation Kit is exactly that: the column-based partner to the Tempus Blood RNA Tube, made by the same manufacturer and designed around the same stabilising chemistry.
The principle is simple. The stabilising reagent in the tube lyses the blood cells and precipitates the RNA, while genomic DNA and proteins stay in solution. After a dilution, a long spin pellets that RNA, a short wash and resuspension follow, and the RNA is then cleaned up on a silica-based filter in a microcentrifuge. The manufacturer quotes 6 to 25 µg of RNA from 3 mL of blood, with very low genomic DNA carry-over.
How does it differ from the magnetic bead workflow? There are no beads, no magnet and no DNase step in the manual, so it is a shorter and simpler procedure, but it is manual only and aimed at larger RNA species such as mRNA and rRNA. Here is the full workflow, step by step.
You'll need
Kit
Applied Biosystems Tempus Spin RNA Isolation Kit (cat. 4380204, 50 preps), used with Tempus Blood RNA Tubes (cat. 4342792). All components are stored at room temperature.
- RNA purification filters
- 2 mL collection tubes
- 1× PBS
- RNA Purification Resuspension Solution
- RNA Purification Wash Solution 1
- RNA Purification Wash Solution 2
- Nucleic Acid Purification Elution Solution
You'll also need
- Blood collected in Tempus Blood RNA Tubes
- Sterile 50 mL conical tubes
- Serological pipettes and pipette tips
- Vortexer
- Microcentrifuge capable of 16,000 × g
- Temperature-controlled centrifuge capable of more than 3,000 × g, with a swing-bucket rotor for 50 mL tubes
- Heating block for microcentrifuge tubes, set to 70 °C
- Absorbent paper
- Gloves, lab coat and eye protection, because this is human blood
Part 1: Before you start
Nothing needs to be prepared. The wash solutions and elution solution come ready to use, and the user guide does not call for any additional ethanol.
Two rules apply to the whole procedure. First, the stabilising reagent must be diluted to a final concentration of 1× with Ca²⁺/Mg²⁺-free PBS before extraction, otherwise yields drop significantly. Second, keep the samples on ice as much as possible.
Part 2: Thaw and dilute the blood
Step 1: Thaw (if frozen)
Thaw frozen Tempus tubes at room temperature (18 to 25 °C). Once thawed, keep them on ice.
Step 2: Transfer to a conical tube
Remove the cap and pour the entire contents of the Tempus tube into a clean 50 mL conical tube.
Step 3: Dilute with 1× PBS
Add 3 mL of 1× PBS (Ca²⁺/Mg²⁺-free) to bring the total volume to 12 mL. If the tube held less than 3 mL of blood, add enough PBS to make up the difference to 12 mL.
Cap the tube properly, then vortex at maximum vortex speed for 30 seconds. Vortexing for less time can clog the filter later. A layer of froth on top is normal.
Part 3: Pellet the crude RNA
Step 4: Pellet
Centrifuge at 4 °C at 3,000 × g for 30 minutes. The RNA pellet is transparent and invisible, so handle the tube gently.
Step 5: Decant and drain
Carefully pour off the supernatant without dislodging the pellet. Leave the tube inverted on absorbent paper for 1 to 2 minutes, then blot the drops of liquid from the rim with clean absorbent paper.
Part 4: Resuspend the RNA
Step 6: Add Resuspension Solution
Add 400 µL of RNA Purification Resuspension Solution, placing the pipette tip at the bottom of the tube so you do not wash blood residue down the inside wall. Vortex briefly to resuspend the pellet.
The resuspended RNA can wait on ice while you set up the next part.
Part 5: Bind and wash on the filter
Between each step, discard the liquid in the waste tube and put the filter back. The manufacturer notes that you can also move the filter into a fresh collection tube each time.
Step 7: Set up and pre-wet
Label an RNA purification filter and insert it into a waste collection tube. Pre-wet the membrane with 100 µL of RNA Purification Wash Solution 1.
Step 8: Load the RNA
Add about 400 µL of the resuspended RNA to the filter and centrifuge for 30 seconds at 16,000 × g.
Step 9: Wash
Wash once with Wash Solution 1 and twice with Wash Solution 2, as laid out in the table below. Then give the membrane a final spin to dry it.
| Wash | Solution | Volume (µL) | Spin |
|---|---|---|---|
| 1 | RNA Purification Wash Solution 1 | 500 | 30 seconds at 16,000 × g |
| 2 | RNA Purification Wash Solution 2 | 500 | 30 seconds at 16,000 × g |
| 3 | RNA Purification Wash Solution 2 | 500 | 30 seconds at 16,000 × g |
| Dry | None | None | 30 seconds at 16,000 × g |
Part 6: Elute
Step 10: First elution
Move the filter to a new, labelled collection tube. Add 100 µL of Nucleic Acid Purification Elution Solution, close the cap, and incubate the entire tube for 2 minutes at 70 °C. Then centrifuge for 30 seconds at 16,000 × g.
Step 11: Re-elute
Add about 100 µL of the collected eluate back onto the filter and centrifuge for 2 minutesat 16,000 to 18,000 × g. No incubation is needed this time.
Step 12: Collect the RNA
Discard the filter. Transfer about 90 µL of the eluate to a new, labelled tube, taking the liquid from the top so you do not disturb the last 10 µL or the pellet at the bottom. Do not throw away the eluate!
Store the RNA at −20 °C, or at −80 °C for the long term.
How do you know it worked?
The manufacturer reports an A260/A280 ratio above 1.9, genomic DNA below 0.05% by weight, and 6 to 25 µg of RNA from 3 mL of blood. With parasitised patient blood, the RNA is a mix of host and parasite RNA, so measure it with a fluorometric method such as Qubit or RiboGreen and check the traces on a bioanalyser rather than relying on the A260/A280 ratio alone.
Unlike the MagMAX kit, this procedure has no DNase step. For gDNA-sensitive work such as qRT-PCR of parasite genes, include no-RT controls, and consider a DNase treatment after elution. That treatment is not part of the manufacturer's protocol.
Troubleshooting tips
- Black or brownish-red filters: the blood was not mixed well with the stabilising reagent after collection. Shake or vortex the tube for 10 to 20 seconds immediately after the draw. If residue got onto the filter, add an extra 500 µL of Wash Solution 1 and another 500 µL of Wash Solution 2, with a 30 second spin at 16,000 × g after each.
- Degraded RNA: residual protein with RNase activity, or lysate exposed to more than 37 °C. Add extra wash steps next time until the membrane looks white, and vortex for the full 30 seconds after the PBS dilution.
- Leaks during vortexing: the conical tube was not capped properly.
- Clogged filter: usually caused by too little vortexing after dilution, or by microclots from poor mixing at the time of blood collection.
Reference
Thermo Fisher Scientific. (2018). Tempus Blood RNA Tube and Tempus Spin RNA Isolation Kit user guide (Publication No. 4379232, Rev. E). Life Technologies Corporation.
Subscribe by Email
Follow Updates Articles from This Blog via Email
.png)